Skip to content
Free Shipping over $299 | Contact Us for Deals
Free Shipping over $299 | Contact Us for Deals

Superior VRT2536 36" Traditional Vent-Free Gas Fireplace With White Stacked Refractory Panels

SKU VRT2536WS
Superior authorized dealer
Original price $809.00 - Original price $809.00
Original price
$809.00
$809.00 - $809.00
Current price $809.00

Free Shipping over $299

  • FREE SHIPPING : All Over United States over $299

  • SPEAK TO AN EXPERT : Call 888-486-2909 or email at cs@dreamwoodliving.com

Superior VRT2536 36" Traditional Vent-Free Gas Fireplace With White Stacked Refractory Panels

The Superior VRT2536 is the 36" firebox in Superior's VRT2500 series of vent-free fireboxes: a heat-circulating, clean-faced cabinet with a 24" tall opening, white stacked refractory panels on the back and sides, a black metal floor and mesh fire screens. It is the enclosure only. The fire comes from a vent-free gas log set and burner that you order separately, and with no chimney or vent pipe, the heat stays in the room.

The firebox takes a vent-free log set listed to ANSI Z21.11.2, rated no more than 40,000 Btu/hr, that fits inside it. Superior's Double-Flame (18" and 24"), Triple-Flame (18" and 24") and Nature-Flame (18" and 24") logs fit; they and their burners are listed below. The included hood must stay on in every installation, and a junction box for an optional blower comes with the firebox.

You can add a single-speed or variable-speed blower, an outside air kit and an arched twin-pane screen door in textured iron. The VRT2500 also comes in 42" (VRT2542). The firebox can't be installed in a bedroom or bathroom, and the room has to be large enough or ventilated for the log set you choose; see Installation Requirements.

Key Features

  • 36" wide, 24" tall opening; inside, 35" wide at the front, 23-1/4" at the back and 17-3/8" deep
  • Vent-free: no chimney or vent pipe
  • Takes ANSI Z21.11.2 vent-free log sets up to 40,000 Btu/hr, ordered separately
  • White stacked refractory panels on the back and sides; black metal floor
  • Heat-circulating, clean-face design
  • Heat deflection hood included and required
  • Mesh fire screens included
  • Textured black powder coat finish
  • Optional single-speed or variable-speed blower
  • Optional outside air kit
  • Optional arched twin-pane screen door in textured iron
  • Listed to ANSI Z21.91 as a ventless firebox enclosure
  • 20 year limited warranty on the firebox

What's Included

  • Firebox with white stacked refractory panels on the back and sides and a black metal floor
  • Black hood (FC36), required in every installation
  • Mesh fire screens and rods
  • Junction box for an optional blower
  • Installation and operation manual

What to Order With It

Required – Vent-free logs, ordered separately (pick one set):

Required – Burner for the logs (pick one: Double-Flame logs take the VD1824 burner; Triple-Flame and Nature-Flame 18" logs take the 18" burner and 24" logs the 24" burner):

Optional – Blower (the FBK-100 needs an on/off wall switch):

Optional – Screen door and outside air:

Optional – Touch-up paint:

Specifications

Model VRT2536WS
Order number F0322
Type Vent-free firebox (ventless firebox enclosure) for a decorative vent-free gas log set
Heat input Set by the log set; 40,000 Btu/hr maximum
Opening 36" W x 24" H
Inside the firebox 35" wide at the front, 23-1/4" at the back, 17-3/8" deep, 24" high
Outside size 41-3/4" W x 37-1/4" H x 20" D
Framed opening 42-1/4" W x 40-1/4" H x 20-1/2" D
Liner White stacked refractory on the back and sides; black metal floor
Hood Black FC36, included and required
Screen Mesh fire screens
Finish Textured black powder coat
Blower Optional FBK-100 (single speed) or FBK-200 (variable speed)
Power None for the firebox; 120 VAC to the junction box for an optional blower
Gas line 1/2" to 1-1/2" inside diameter, through the left or right side to the log set burner
Venting None (vent-free); the room must supply enough combustion air
Shipping weight 158 lb
Listing ANSI Z21.91 ventless firebox enclosure (PFS report F14-168), for ANSI Z21.11.2 decorative vent-free log sets
Approved locations Not bedrooms, other sleeping rooms or bathrooms; not recreational vehicles
Warranty 20 year limited (see Warranty below)

The firebox doesn't make heat on its own. The Btu rating, ignition and remote all come from the log set and burner you choose, and the room size rules under Installation Requirements depend on that input.

Dimensions and Framing

Firebox dimensions

Opening width 36"
Opening height 24"
Overall width 41-3/4"
Overall height 37-1/4"
Width at the back 23-1/2"
Depth 20"
Base to the bottom of the opening 5-3/4"

Inside the firebox (for sizing logs)

Front width 35"
Rear width 23-1/4"
Depth 17-3/8"
Height 24"

Framing

Opening width 42-1/4"
Opening height 40-1/4"
Depth to the finished back wall of the chase 20-1/2"
Corner installation, across the front from wall to wall 63-1/2"
Corner installation, along each wall from the corner 44-1/4"

Measure the framed depth to the finished surface of the back wall, so allow for drywall or other finish. Nail the firebox to the side framing through the full-length tabs at the top and bottom of the front face with 8d nails, and don't fill the space around it with insulation. The other corner framing dimensions are in the installation manual.

Installation Requirements

  • Room air: a vent-free log set uses the air in the room. The space must hold at least 50 cubic feet for every 1,000 Btu/hr of all the gas appliances in it, counting adjoining rooms without doors. A 40,000 Btu/hr log set alone needs 2,000 cubic feet. A smaller space needs ventilation openings to another room or to the outdoors, as set out in NFPA 54 and the log set's manual.
  • Bedrooms and bathrooms: the firebox can't be installed in a bedroom, other sleeping room or bathroom, or in a recreational vehicle.
  • Log set: use only a vent-free log set listed to ANSI Z21.11.2, rated no more than 40,000 Btu/hr, that fits the firebox. Don't burn wood, a vented gas log set or anything else in it.
  • Hood: the included hood must be on in every installation, and the mantel clearances depend on it. Don't remove it or swap in a hood that comes with a log set.
  • Side walls and ceiling: keep a side wall at least 16" from the side of the firebox opening and the ceiling at least 40" above the top of the opening. No combustible material can be closer than 3" to the side of the opening, and anything that sticks out from the wall, such as a mantel leg or bookshelf, needs more room the further it sticks out (5" out needs 6" from the opening; the chart is in the manual).
  • Mantel: a combustible mantel or trim up to 3" deep can be 9" above the firebox opening; deeper ones go higher, up to 8" deep at 18" (a 5" mantel needs about 13"). Superior recommends high-temperature paint, rated 175 degrees F or higher, on the underside of a mantel.
  • Wall above: the first 3" of wall above the top of the firebox, up to the header, must be non-combustible. A header can touch the top spacers but can't rest on them, and the spacers can't be removed or cut. All framing above the firebox must support itself.
  • Front: keep curtains, furniture and other flammable objects at least 42" from the front.
  • Facing: only non-combustible materials such as marble, stone, tile or brick can overlap the black front face; seal the joints with non-combustible caulk. Non-combustible materials at least 1/2" thick can go above and beside the opening without restriction, as long as they don't block the heat-circulating air openings.
  • Hearth and floor: no hearth extension is required. A raised one can be combustible (not carpet or vinyl) if it is no higher than the firebox floor, 5-3/4" above the base. The firebox can sit on a combustible floor on a fully supported, level base; on carpet or vinyl, put a metal or wood panel under it.
  • Gas: run a 1/2" to 1-1/2" inside diameter gas line through the access on either side before the wall is closed, with a sediment trap upstream. Propane needs an external regulator that holds tank pressure to 13" WC or less. Seal the holes with high-temperature caulk or unfaced fiberglass.
  • Power: only an optional blower needs power. Run a 3-wire, 120 VAC, 60 Hz supply to the right side before the firebox is framed in, even if the blower will be added later; the wiring must be done by a licensed electrician.
  • Cold climates: seal cracks around the firebox with non-combustible material and insulate outside wall cavities. On a cement slab, a plywood platform under the firebox keeps cold from coming up into the room.
  • Drafts: don't let fans blow into the firebox; drafts change the flame.
  • Burn-in: the first few fires give off an odor from curing paint. Ventilate the house and don't run the blower until it passes.
  • Massachusetts: installation and repair must be done by a licensed plumber or gas fitter, following 527 CMR 30. The flexible gas connector can't be longer than 36", the shutoff must be a T-handle valve, the firebox can't go in a bedroom or bathroom, and a working smoke detector is required in the area where it is installed.
  • Installation: must be installed by a qualified installer following the installation manual, the log set's manual and local codes. Superior calls for an inspection by a professional service person before first use and once a year.

Frequently Asked Questions

Does it come with logs?
No. Order a vent-free log set and a matching burner, both listed above: Double-Flame logs take the VD1824 burner; Triple-Flame and Nature-Flame 18" logs take the 18" burner and 24" logs the 24" burner. Any vent-free log set listed to ANSI Z21.11.2, rated 40,000 Btu/hr or less, that fits inside (35" wide at the front, 23-1/4" at the back, 17-3/8" deep, 24" tall) can also be used.

Does it need a chimney?
No. The log set burns room air and the heat stays in the room, so there is no vent pipe to run. In exchange, the room has to be big enough or ventilated for the log set's input.

Can it go in a bedroom or bathroom?
No. It can't be installed in a bedroom, other sleeping room or bathroom.

How much heat will it give?
That depends on the log set. Superior's 24" Triple-Flame and Nature-Flame burners run up to 39,000 Btu/hr on natural gas, and the Double-Flame burner up to 36,000. The firebox allows up to 40,000.

Do I need the blower?
No, it's optional. It draws room air in through the side slots, warms it around the firebox and sends it out at the top of the opening. The FBK-100 runs at one speed from an on/off wall switch; the FBK-200 comes with a variable speed wall control. Power has to be run to the firebox before the wall is closed.

Can I take the hood off?
No. The FC36 hood must stay on in every installation; the mantel and trim clearances are based on it.

Can I put a mantel above it?
Yes. A combustible mantel up to 3" deep can sit 9" above the opening, and deeper mantels go higher (8" deep at 18"). A non-combustible mantel can go at any height. Our guide to fireplace heat management explains ways to keep the wall above cooler.

Warranty

Superior's 20 Year Limited Warranty covers the VRT2536 against defects in materials and workmanship:

  • Firebox body: 20 years
  • Optional blowers: 1 year
  • Parts not listed: 90 days
  • Labor: paid at IHP rates for the covered part's warranty period, up to five years

Trim and paint are not covered. The warranty is for the original owner of a fireplace installed in the US or Canada. Full terms are in the warranty certificate.