Superior LTF18WT Triple-Flame 18" Wild Timber Logs, Concrete
Free Shipping over $299
- FREE SHIPPING : All Over United States over $299
- SPEAK TO AN EXPERT : Call 888-486-2909 or email at cs@dreamwoodliving.com
Free Shipping over $299
The Superior LTF18WT is an 18" Wild Timber set of concrete logs for Superior's Triple-Flame vent-free burner. The triple burner adds an extra row of flame behind the logs and a glowing ember bed at its base, so the fire has depth from back to front, and the system is heater rated at 99% efficiency with a wood-burning grate look.
The logs come without a burner. Superior pairs 18" Triple-Flame logs with the 18" TF18 burner, offered in millivolt, variable or electronic control for natural gas or propane. The set needs a firebox at least 28" wide at the front, 20" at the back and 19" high, and it's also listed for vented use with a damper clamp. The same style comes as the 24" Wild Timber (LTF24WT) and 30" Wild Timber (LTF30WT), and the 18" Rugged Stack (LTF18RS) fits the same burner.
Required – One 18" Triple-Flame burner (natural gas or propane):
Optional – Remotes and wall controls (millivolt burner):
Optional – Installation and finishing:
| Model | LTF18WT |
| Order number | F2078 |
| Series | Triple-Flame vent-free gas logs |
| Log size | 18" |
| Logs | 8, concrete |
| Burner | TF18 millivolt, variable or electronic, sold separately |
| Burner input | Up to 30,000 Btu/h |
| Efficiency | Heater rated, 99% |
| Fuel | Natural gas or propane, set by the burner |
| Venting | Vent-free; also listed for vented use with the GA6080 damper clamp |
| Minimum firebox | 28" front, 20" rear, 19" high, 14" deep |
| Warranty | Logs and grate: 3 years (see Warranty below) |
| Front width, minimum | 28" |
| Rear width, minimum (measured 14" back) | 20" |
| Height, minimum | 19" |
| Depth, minimum | 14" |
| Side wall | 16" minimum from the fireplace |
| Ceiling | 42" minimum above the top of the fireplace opening |
| Floor | 5" minimum |
| Front | 36" to furniture, drapes and other combustibles |
Superior vent-free fireboxes this set fits: VRT2536, VRT2542, VRT3136, VRT3142, VRT3236, VRT3242, VRT3536, VRT3542, VRT4536, VRT4542, VRT4550, VRT6036, VRT6042, VRT6050, VRE4236, VRE4242.
Which burner does it need?
One Superior TF18 Triple-Flame burner. Superior pairs 18" logs with the 18" TF18 and 24" or 30" logs with the 24" TF2430, each in millivolt, variable or electronic control and natural gas or propane.
Which control should I pick?
The millivolt burner runs from its control knob and is remote ready for the RCKIT4001, TRC and TSRC remotes and the GWMT1 and GWMS2 wall controls. The variable burner includes a ProFlame remote with manual and thermostat modes and five flame heights. The electronic burner includes an EcoFlow touch screen remote with manual and thermostat modes and three flame heights.
Will it fit my fireplace?
The firebox needs to be at least 28" wide at the front, 20" wide at the back (measured 14" in), 19" high and 14" deep. It also has to be a wood-burning masonry fireplace, a UL127 factory-built fireplace whose instructions allow unvented gas logs, or a listed vent-free firebox.
How big a room does it need?
Superior uses the National Fuel Gas Code method: the room's volume in cubic feet, counting adjoining rooms open through doorways without doors, times 20 is the most Btu/h the space can support. At 30,000 Btu/h the burner alone needs about 1,500 cubic feet, and any other gas appliance in the space that isn't direct-vent adds to the total. Smaller or very tightly built spaces need extra fresh air brought in.
Can I run it with the damper open?
Yes. The logs are also listed for vented use in a wood-burning fireplace. The GA6080 damper clamp holds the damper permanently open, leaving at least 39 sq in of flue opening on a 6 to 15 ft chimney or 29 sq in on a 15 to 30 ft chimney. Vented operation is required if the fireplace doesn't meet the vent-free clearances or local codes don't allow vent-free logs.
Where do the embers go?
Only on the front flat burner: Platinum Bright Embers just behind the horizontal ports, and Glowing Embers in the areas away from the ports. Too much ember material, or embers anywhere else, can cause soot or carbon monoxide.
Will it heat during a power outage?
Yes. None of the burners needs house power: the millivolt and variable versions run off a standing pilot, and the electronic version runs on batteries in its power supply and remote. Superior says the logs can be your main heat source during an outage; the rest of the time they're meant as supplemental heat alongside your furnace.
Is a smell normal the first few times?
A slight smell or haze during the first fires comes from manufacturing residue and the logs curing, and it goes away. Odors later on usually come from things in the room air, such as cleaning products, paint or candles, mixing with the combustion air.
What if the logs start to soot?
Soot means a flame is touching a log. Turn the logs off, let them cool and set each piece back exactly where the placement instructions show; with the burner on HI, no flame should touch any log. Don't add rocks or extra logs on the burner. If it still soots, have a qualified service technician check the burner's air openings.
How do I care for it?
Turn it off and let it cool for at least 30 minutes first. Clean the burner, pilot and air inlet holes with a vacuum, a soft brush or compressed air under 30 psi about every three months while you're using it and before each heating season, and have it inspected by a qualified service person every year. Replace any log that's broken or chipped dime-size or larger, and put each one back exactly as the instructions show.
Superior's Limited Three Year Warranty on gas log sets covers defects in materials and workmanship this way:
Wear and tear, misuse, faulty installation and damage from burning wood or other solid fuel aren't covered. The warranty is for the original owner of a gas log set installed in the US or Canada. Full terms are in the TF18 and TF2430 Millivolt Burner Installation and Operation Manual.