Skip to content
Free Shipping over $299 | Contact Us for Deals
Free Shipping over $299 | Contact Us for Deals

Superior DRT3040 40" Traditional Direct Vent Gas Fireplace

SKU DRT3040DMN-E
Superior authorized dealer
Original price $2,409.00 - Original price $2,629.00
Original price
$2,409.00
$2,409.00 - $2,629.00
Current price $2,409.00

Free Shipping over $299

Not sure which options you need? Call 888-486-2909Chat with us

Superior DRT3040 40" Traditional Direct Vent Gas Fireplace

The Superior DRT3040 is a 40" traditional direct vent gas fireplace with a high-definition ceramic fiber log set and glowing embers behind a 34-1/4" x 24-1/2" window.

You pick the face that suits the room, and millivolt or electronic ignition on natural gas or propane.

Video

Play video: Superior DRT3000 Direct Vent Gas Fireplace

The Superior DRT3040: A Traditional Fire with the Face You Choose

The DRT3040 is the 40" size of Superior's DRT3000 traditional direct vent gas fireplaces: a 17" deep firebox with a high-definition ceramic fiber log set, glowing embers, a black painted interior and a glass viewing area 34-1/4" wide and 24-1/2" tall. It runs from 24,000 down to 19,000 Btu/hr on natural gas and from 24,000 to 18,000 on propane.

You choose the ignition and fuel when you order. The millivolt models (DRT3040DMN-E natural gas, DRT3040DMP-E propane) light with a piezo igniter and run the fire with no house power. The electronic models (DRT3040DEN-E, DRT3040DEP-E) use IPI/CPI ignition on 120 V with four AA batteries as backup. The vent can leave from the top or the back of the fireplace in 4-1/2" x 7-1/2" Superior Secure Vent or Secure Flex pipe.

The face is your choice, and one facade is required: the Vista frame, or a Reflection or Craftsman designer facade in black or warm chestnut. Each comes with the protective screen barrier and the hood. You also pick a control, and you can add a blower, a stacked ceramic or black porcelain liner, or a stainless surround. The Superior DRT2040 is the same size with the Vista facade included, and the Superior DRT3540 adds a blower, interior lighting and a remote. The DRT3000 series also comes in 35" (DRT3035) and 45" (DRT3045).

Compare it with our other direct vent gas fireplaces, or see the full Superior fireplace lineup.

Features

  • Viewing area: 34-1/4" x 24-1/2" glass viewing area on a 40-1/4" wide fireplace.
  • Heat input: natural gas 24,000 to 19,000 Btu/hr; propane 24,000 to 18,000 Btu/hr.
  • Ignition choice: millivolt or electronic IPI/CPI ignition, chosen when you order.
  • Power outage: millivolt models run the fire with no house power; electronic models run on four AA batteries in a power outage (blower excluded).
  • Combination flue: vents from the top or the back.
  • Framing depth: mid-size 17" depth saves floor space.
  • Facade choice: one facade required: Vista frame, Reflection or Craftsman, each with a protective screen barrier.
  • Log set: high-definition ceramic fiber log set with glowing embers and a black painted interior; stacked ceramic and black porcelain liners available.
  • Glass: tempered glass front.
  • Options: optional blower, remote controls, wall switches and thermostats.
  • Surround option: stainless surrounds available in three- and four-sided versions.
  • Bedroom approved: listed for bedrooms and manufactured homes.
  • 20 year limited warranty: covers the body, firebox and barrier.

What's Included

  • Millivolt valve with piezo igniter, or electronic IPI/CPI ignition with a battery holder for four AA batteries (by model)
  • High-definition ceramic fiber log set and a bag of glowing embers
  • Tempered glass front and black painted interior
  • Non-combustible fireboard with side and center brackets
  • Header shield and elbow/wall heat shield
  • Two vent restrictors, two vent cover plates and a rear flue cover
  • 15 ft of two-conductor wire for a wall control

What to Order With It

Required – Facade (choose one; includes the screen barrier and hood):

Required – Control (choose one):

Required – Venting (4-1/2" x 7-1/2", ordered separately):

Optional – Firebox liners:

Optional – Blower:

Optional – Surround and stone stop:

Optional – Gas conversion, embers and touch-up:

Specifications

Models DRT3040DMN-E (natural gas, millivolt), DRT3040DMP-E (propane, millivolt), DRT3040DEN-E (natural gas, electronic), DRT3040DEP-E (propane, electronic)
Superior item numbers F4997 (DMN-E), F4998 (DMP-E), F4999 (DEN-E), F5000 (DEP-E)
Type Traditional direct vent gas fireplace, single-sided, sealed combustion
Input, natural gas 24,000 Btu/hr high, 19,000 Btu/hr low
Input, propane 24,000 Btu/hr high, 18,000 Btu/hr low
Efficiency 64.8% P4 natural gas, 63.8% P4 propane
Glass viewing area 34-1/4" W x 24-1/2" H
Fireplace size 40-1/4" W x 37-1/8" H x 17" D
Framed opening 40-7/8" W x 41-1/4" H x 18-1/2" D (add 1/8" per side)
Ignition Millivolt with piezo igniter, or electronic IPI/CPI with four AA battery backup
Power Millivolt: none needed for the fire, 120 VAC for an optional blower. Electronic: 120 VAC, 60 Hz, unswitched, to the junction box on the right side
Gas connection 1/2" supply line to the left side; flexible connector and 1/2" shutoff valve installed at the factory
Gas inlet pressure Natural gas 5" to 10.5" WC; propane 11" to 13" WC
Venting Direct vent, top or rear, 4-1/2" x 7-1/2": Superior Secure Vent (rigid), Secure Flex (flexible) or Z-Flex GA
Vent run 6 to 60 ft straight up; horizontal runs up to 25 ft with the vertical rise the vent chart calls for; up to three 90° elbows
Glass and barrier Tempered glass; screen barrier comes with the required facade
Logs and interior High-definition ceramic fiber log set, glowing embers, black painted interior
Altitude 0 to 4,500 ft with the standard orifices
Listing ANSI Z21.88 / CSA 2.33 and CSA 2.17, vented gas fireplace heater (PFS report F13-094)
Approved locations Bedrooms; aftermarket, permanently located manufactured homes (USA only)
Shipping weight 129 lb
Warranty 20 year limited (see Warranty below)

Efficiency figures are P4 ratings from Superior's installation manual, Table 2. P4 is the Canadian CSA P.4.1 fireplace efficiency rating; Superior doesn't publish an AFUE figure for this series.

Dimensions and Framing

Superior DRT3040 dimension drawing with front, top and side views

Fireplace dimensions

Overall height (A) 37-1/8"
Front face height (B) 34-5/8"
Glass viewing height (C) 24-1/2"
Glass viewing width (D) 34-1/4"
Overall width (E) 40-1/4"
Width at the back (F) 30"
Vent center from the side at the back (G) 15"
Width at the base of the front (H) 37-7/8"
Vent center from the back (I) 6-7/8"
Overall depth (J) 17"
Vent center from the front 10-1/8"

Letters match the drawing above.

Superior DRT3040 framing drawing with top vent framing for one 90 degree elbow

Framing

Opening width (K) 40-7/8"
Opening height (L) 41-1/4", including the 4" top standoffs
Depth (N) 18-1/2"
Top vent, minimum height to the vent framing (M) 43-3/4"
Rear vent, minimum height to the vent framing (O) 28-1/4"

Framing is 2x4 or larger. The opening sizes are minimums, and Superior recommends an extra 1/8" per side. The depth assumes 1/2" drywall. Framing for Secure Flex top venting and for corner installations is in the installation manual.

Installation Requirements

  • Clearances to combustibles: 1-1/2" to the outer wrapper at the back and 1/2" at the sides, 0" at the spacers, the top standoffs and the floor. With top venting, nothing combustible may touch the rear flue cover.
  • Ceiling: at least 64" from the bottom of the fireplace to the ceiling.
  • Header: a header can touch the bent-up 4" top standoffs but can't rest on them or be notched around them. All framing above the fireplace must support itself.
  • Front: keep 36" clear in front of the glass.
  • Side walls: the fireplace can't be recessed behind the wall surface. With one side flush to a wall, the wall on the other side must not extend past the front edge of the unit. At 6" or more from the side, a combustible side wall can run any length, and combustible mantel legs must stay within the 45 degree safe zone shown in the manual.
  • Mantel: a 12" deep combustible mantel needs to be at least 16" above the fireplace opening and a 2" deep one at least 6", per the mantel chart in the manual. Non-combustible mantels can go at any height, but nothing may hang below the hood.
  • Wall finish: combustible materials can come down to the top of the non-combustible board that ships with the fireplace. Non-combustible facing up to 6" deep can overlap the face, as long as it doesn't cover the glass or block removal of the facade. With a designer facade and thick facing, use the stone stop kit.
  • Shelf or TV above: a combustible shelf must be at least 52" above the base of the fireplace with top venting and a rigid Secure Vent elbow, 54" with a Secure Flex elbow, or 46" with rear venting. Don't insulate the space between the fireplace and the shelf. A TV above must stay within its maker's temperature rating.
  • Facade: the fireplace can't be run until the required facade is installed. The facade carries the screen barrier and the hood.
  • Floor: no hearth extension is required. On carpet, vinyl or any combustible floor other than wood, set the fireplace on a metal or wood panel the full width and depth of the unit.
  • Venting: use only Superior Secure Vent, Secure Flex or Z-Flex GA pipe in the 4-1/2" x 7-1/2" size, from the top or the back of the fireplace. Straight vertical runs are 6 to 60 ft, and horizontal runs can reach 25 ft with the vertical rise the vent chart calls for, with up to three 90° elbows. Secure Flex on a rear vent horizontal termination needs at least 1 ft of vertical rise. Keep 3" of clearance above horizontal vent runs and 1" at the sides and bottom.
  • Gas: run a 1/2" gas line to the left side of the fireplace. Inlet pressure must be 5" to 10.5" WC on natural gas or 11" to 13" WC on propane.
  • Power: millivolt models need no power for the fire; if a blower may be added, have power run when the fireplace goes in. Electronic models need an unswitched 120 VAC supply to the junction box, with the batteries as backup only. The FBK-250 blower runs from the unswitched outlet; the FBK-100 and FBK-200 also need a switched circuit to a wall switch box, run at the time of installation.
  • Control: one control must be connected before the fireplace can run, using the 15 ft of two-conductor wire in the box. On millivolt models, never connect a wall switch to 120 V.
  • Altitude: the standard orifices cover 0 to 4,500 ft. Above that, the input has to be reduced; ask your gas supplier.
  • Massachusetts: installation and repair must be done by a licensed plumber or gas fitter. The flexible gas connector can't be longer than 36", and the shutoff must be a T-handle valve. A horizontal termination less than 7 ft above grade also needs a hard-wired carbon monoxide detector with battery backup on the floor where the fireplace is, and a GAS VENT DIRECTLY BELOW sign outside.
  • Manufactured homes: ground the fireplace to the chassis and don't cut or weaken the cross members. It must run on the gas shown on its rating plate unless a certified conversion kit is used.
  • Installation: must be installed by a qualified installer following the installation manual and local codes. Superior calls for an inspection by a qualified service person before first use and once a year.

Bring the Superior DRT3040 Home with Dreamwood Living

The DRT3040 suits a room where the look of the face matters as much as the fire. Reach out to our team for help matching a facade, liner and control.

FAQs

Millivolt or electronic ignition: which should I order?
Millivolt models light a standing pilot with a piezo igniter and run the fire with no house power, which suits cabins and homes with frequent outages. Electronic models light the pilot only when the fireplace is turned on (IPI) and run on house power with four AA batteries as backup. Both use the same framing, venting and facades. Our millivolt vs electronic ignition guide compares pilot gas use and cost.

Do I need a remote or wall switch with the DRT3040?
Yes. One control must be used on both versions: an on/off wall switch, a thermostat or a remote, and on millivolt models a unit-mounted rocker switch also works. None comes in the box, so pick one from the list above. A 15 ft run of two-conductor wire ships with the fireplace for a wall control.

Can it vent out the back?
Yes. It has a combination flue: the vent can leave from the top or from the back, and the vent cover plates for switching it ship with the fireplace. A rear vent can go straight out through an outside wall behind the fireplace, and it allows the lowest shelf above the fireplace.

Can I put a TV above it?
Yes, if the shelf or TV mount is at least 52" above the base of the fireplace with top venting (46" with rear venting) and the TV stays within its maker's temperature rating. Don't insulate the space between the fireplace and the shelf. Our guide to fireplace heat management explains other ways to keep the wall above cooler.

Will it work during a power outage?
Yes. Millivolt models need no power to run the fire, and electronic models run on four AA batteries when the power is out. A blower won't run until power returns.

Can I change it from natural gas to propane, or the other way?
Yes, with Superior's conversion kit for your ignition type: GCKSIT3040MNP or GCKSIT3040ENP for natural gas to propane, GCKSIT3040MPN or GCKSIT3040EPN for propane to natural gas. In a manufactured home, the fireplace may only run on the gas shown on its rating plate unless a certified kit is used.

What's the difference between the DRT3040, DRT2040 and DRT3540?
All three are 40" Superior traditional direct vent fireplaces with the same framing. The DRT2040 includes the Vista facade and runs at 21,000 Btu/hr high on natural gas. The DRT3040 runs at 24,000 Btu/hr with a high-definition log set, and you pick the facade. The DRT3540 is electronic only and adds a blower, interior lighting, a remote and ceramic glass at 33,000 Btu/hr; it needs a facade and a liner.

Can it go in a bedroom?
Yes. The DRT3040 is listed for bedrooms and for aftermarket, permanently located manufactured homes in the USA, where local codes allow.

Documents & Downloads

Warranty

Superior's 20 Year Limited Warranty covers the DRT3040 against defects in materials and workmanship:

  • Fireplace body, firebox and barrier: 20 years
  • Burner, gas components and gaskets: 1 year
  • Tempered glass: 1 year, replacement
  • Optional blowers and remote controls: 1 year
  • Parts not listed: 90 days
  • Labor: paid at IHP rates for the covered part's warranty period, up to five years

Vent components, trim and paint are not covered. The warranty is for the original owner of a fireplace installed in the US. Full terms are in the warranty certificate.