Empire Breckenridge Deluxe 42" Vent-Free Gas Firebox
The Empire Breckenridge Deluxe 42" gives a vent-free gas log set a finished place in the wall: a zero-clearance firebox that frames in like a fireplace, with no chimney or vent pipe behind it.
Choose a flush or louvered front (model numbers VFD42FB0F, VFD42FB0L, VFD42FB2MF and VFD42FB2ML). The 2MF and 2ML models come with a refractory liner; the 0F and 0L models have a plain interior that takes an optional liner. It is 19" deep and holds any listed vent-free log set up to 40,000 Btu/hr that fits.
The Empire Breckenridge Deluxe 42": A Ventless Fireplace for a Framed Wall
With a 40" x 24 1/4" opening, the Deluxe 42" suits a family room, a great room or an open living area. The side and back flanges are zero clearance to combustibles, and the black hood comes in the box.
Gas reaches the log set through a 3/8" line on either side. Power is only needed if you add the FBB5 blower, and the log set you choose sets the flame and the heat, up to 40,000 Btu/hr.
See every vent-free model we carry in our vent-free fireplaces collection.
Weighing vent-free against direct vent? Our guide to direct vent vs. vent-free gas fireplaces covers the pros, the cons and where vent-free isn't allowed.
Features
-
Vent-free: holds a listed vent-free gas log set up to 40,000 Btu/hr, with no chimney or vent.
-
Size: 40" x 24 1/4" opening, 19" deep.
-
Flush or louvered front: models ending F are flush; models ending L are louvered.
-
Refractory liner included: on the 2MF and 2ML models; optional liners fit the 0F and 0L.
-
Zero clearance: 0" to combustibles at the side and back flanges.
-
Black hood included: the extended hood (VB4H42BL) is for facing more than 1" thick.
-
Optional blower: the FBB5 automatic blower, with the SCV1 variable speed control.
-
Finishing options: door sets, louvers, a steel outer frame and cabinet mantels.
Package Contents
- Breckenridge Deluxe 42" vent-free firebox, flush or louvered
- Black hood
- Refractory liner, on the 2MF and 2ML models
A vent-free log set is required and ordered separately (see below).
What to Order With It
The firebox ships with its black hood. A vent-free log set is required before it can be used.
Required – Vent-free log set:
- Any listed ANSI Z21.11.2 vent-free gas log set of no more than 40,000 Btu/hr whose minimum firebox size fits this firebox (see the log set's manual); sold separately
Optional – Liners:
Optional – Accessories:
Optional – Extended hood (needed when the facing material is more than 1" thick, such as stone or brick):
Optional – Louvers (louvered models only):
Optional – Door set (needs the VBY42SBL door frame with barrier):
-
Door Set, Black, Mission Arch (VBR42SMBL)
-
Door Set, Hammered Pewter, Mission Arch (VBR42SMHP)
-
Door Set, Black, Arch (VBR42SCBL)
-
Door Set, Hammered Pewter, Arch (VBR42SCHP)
-
Door Frame, Black, Arch (VBY42SBL)
Optional – Outer frame, for flush or louvered models:
Optional – Mantels (cabinet mantels need the 3-piece outer frame):
-
Cabinet Mantel with Base, Cherry (EMBF4SC)
-
Cabinet Mantel with Base, Dark Oak (EMBF4SDO)
-
Cabinet Mantel with Base, Oak (EMBF4SO)
-
Cabinet Mantel with Base, Unfinished Hardwood (EMBF4SUH)
-
Cabinet Mantel with Base, White (EMBF4SW)
-
Corner Cabinet Mantel with Base, Cherry (EMBC4SC)
-
Corner Cabinet Mantel with Base, Dark Oak (EMBC4SDO)
-
Corner Cabinet Mantel with Base, Oak (EMBC4SO)
-
Corner Cabinet Mantel with Base, Unfinished Hardwood (EMBC4SUH)
-
Corner Cabinet Mantel with Base, White (EMBC4SW)
Specifications
| Model numbers |
VFD42FB0F, VFD42FB0L, VFD42FB2MF, VFD42FB2ML |
| Type |
Universal vent-free firebox (ANSI Z21.91 ventless fireplace enclosure) |
| Log set |
Required, sold separately: a listed ANSI Z21.11.2 vent-free gas log set of no more than 40,000 Btu/hr whose minimum firebox size fits this firebox (check the log set's manual) |
| Framing (rough opening) |
44 1/2" W x 35 3/4" H x 18 3/4" D (add 3 3/4" to the height with the flush mantel base) |
| Firebox dimensions |
44" W x 35" H x 19" D |
| Firebox opening |
40" x 24 1/4" (W x H) |
| Front |
Flush (models ending F) or louvered (models ending L) |
| Liner |
Refractory liner included on 2MF/2ML models; optional on 0F/0L models |
| Hood |
Black hood included |
| Gas connection |
3/8" line for the log set, either side |
| Blower |
Optional (FBB5) |
| Manufactured (mobile) home |
May be installed in an aftermarket, permanently located manufactured home (USA only) or mobile home where local codes allow |
| Style |
Traditional |
Installation Requirements
-
Log set: install only a listed ANSI Z21.11.2 vent-free gas log set of no more than 40,000 Btu/hr that fits this firebox, and follow the log set's own instructions, including its room-size and bedroom/bathroom rules, as well as this manual.
-
Clearances: the side and back flanges are zero clearance to combustibles; keep at least 6" from the inside of the firebox to a perpendicular combustible side wall.
-
Top and framing: combustible finishing materials need 3/4" clearance to the top of the unit; frame with 2 x 4 lumber or heavier, with headers at least 3/4" above the firebox.
-
Ceiling: at least 42" from the top of the hood to the ceiling, and at least 84" from floor to ceiling.
-
Front: leave at least 36" clear in front of the firebox. The supplied hood (or an optional hood) must be installed before use.
-
Mantel: a combustible mantel must meet the mantel chart in the installation manual.
-
Floor: on carpet, tile or any combustible floor other than wood, set the firebox on a metal or wood panel the full width and depth of the unit. Hearth extensions are recommended but not required.
-
Gas: the firebox takes a 3/8" gas line for the log set, through access holes on either side; propane installs need an external regulator limiting supply pressure to 14" w.c. In Massachusetts a flexible connector may not exceed 3 ft, the installation must be made by a licensed plumber or gas fitter, and unvented heaters are not allowed in bedrooms or bathrooms.
-
Power: only needed for the optional blower or light: the junction box on the lower right must be pre-wired when the firebox is installed, grounded per code, controlled by a wall switch or the SCV1 speed control.
-
Installation: must be installed by a qualified installer per the installation manual and local codes.
Make It Yours: Liners, Doors and Mantels
On the 0F and 0L models, the liner sets the backdrop for the logs: aged brick, banded brick, traditional brick, stacked limestone or black porcelain.
Arch and mission arch door sets come in black or hammered pewter and mount on the door frame with barrier (VBY42SBL). Louvered models take arch or mission louvers, a steel outer frame in black or hammered pewter finishes the edge, and cabinet or corner cabinet mantels in cherry, dark oak, oak, white or unfinished hardwood complete the wall. Cabinet mantels need the 3-piece outer frame.
Bring the Breckenridge Deluxe 42" Home with Dreamwood Living
The Deluxe 42" suits a room where you want a log fire in the wall without running a chimney or vent pipe.
Reach out to our team and we will help you match a vent-free log set to the firebox and pick the liner, front and mantel.
FAQs
Which Breckenridge is right for me?
The Deluxe 42" is 19" deep with a 40" x 24 1/4" opening, in flush or louvered models. The Breckenridge comes in three trims, all built for a listed vent-free log set up to 40,000 Btu/hr. Deluxe (32", 36" and 42") is the shallowest, 16 1/2" deep for the 32" and 19" for the 36" and 42", in flush or louvered models, some with a refractory liner included. Premium (32", 36" and 42") is 20.6" deep with a taller 27.4" opening, flush or louvered. Select (32", 36" and 42") is flush only and 23 3/16" deep, with a 31 5/8" tall opening. There are also Premium 36" see-through and peninsula models, which come with a banded brick liner.
What do I need to order with it?
A listed ANSI Z21.11.2 vent-free gas log set of no more than 40,000 Btu/hr whose minimum firebox size fits this firebox; check the log set's manual. Liners (for the 0F and 0L models), doors, louvers, the blower and mantels are optional. If the facing is more than 1" thick, such as stone or brick, add the extended hood (VB4H42BL).
Does it need a chimney or vent?
No. It is a vent-free firebox, so there is no chimney or vent pipe. It takes a 3/8" gas line for the log set, and power is only needed for the optional blower. The log set's own manual sets the rules for the room it goes in, and some areas limit vent-free appliances; our direct vent vs. vent-free guide covers where vent-free isn't allowed.
How big is the framing?
44 1/2" wide, 35 3/4" high and 18 3/4" deep. Add 3 3/4" to the height with the flush mantel base.
Documents & Downloads
Warranty
Empire limited warranty for Breckenridge vent-free fireboxes, from the warranty section of the installation manual:
- Combustion chamber and heat exchanger: limited lifetime parts, with 5 years of limited labor
- All other components, except remote controls, thermostats, accessories and replacement parts: 5 years parts and labor
- Remote controls, thermostats, accessories and parts: 1 year parts
The vent-free log set installed in the firebox has its own warranty. The firebox warranty applies to the original purchaser. Full terms, including what is not covered, are in the warranty section of the installation manual.