Empire Breckenridge Premium 32" Vent-Free Gas Firebox
The Empire Breckenridge Premium 32" opens taller than the Deluxe, 31" x 27.4", so the vent-free log set has more room to show, in a zero-clearance box that needs no chimney or vent pipe.
It comes with a flush or louvered front (model numbers VFP32FB0F and VFP32FB0L) and holds any listed vent-free gas log set up to 40,000 Btu/hr that fits. It is 20.6" deep, and the black hood is included.
The Empire Breckenridge Premium 32": More Firebox for the Log Set
The Premium 32" is deeper than the Deluxe, at 20.6", with a taller 27.4" opening, and suits a den, a study or a smaller family room. The side and back flanges are zero clearance to combustibles, and two shoulder bolts on the unit hold the 3/4" gap combustible finishing needs at the top.
Gas reaches the log set through a 3/8" line on either side. Power is only needed for the optional FBB5 blower or LK3 lighting kit, and the log set you choose sets the flame and the heat, up to 40,000 Btu/hr.
See every vent-free model we carry in our vent-free fireplaces collection.
Weighing vent-free against direct vent? Our guide to direct vent vs. vent-free gas fireplaces covers the pros, the cons and where vent-free isn't allowed.
Features
-
Vent-free: holds a listed vent-free gas log set up to 40,000 Btu/hr, with no chimney or vent.
-
Taller opening: 31" x 27.4", with a 20.6" deep firebox.
-
Flush or louvered front: the model ending F is flush; the model ending L is louvered.
-
Zero clearance: 0" to combustibles at the side and back flanges.
-
Black hood included: the extended hood (VB4H32BL) is for facing more than 1" thick.
-
Optional liners: aged brick, banded brick, traditional brick or stacked limestone.
-
Optional blower and light: the FBB5 automatic blower with SCV1 speed control, and the LK3 lighting kit.
-
Finishing options: door sets, louvers and a steel outer frame for louvered models.
Package Contents
- Breckenridge Premium 32" vent-free firebox, flush or louvered
- Black hood
A vent-free log set is required and ordered separately (see below).
What to Order With It
The firebox ships with its black hood. A vent-free log set is required before it can be used.
Required – Vent-free log set:
- Any listed ANSI Z21.11.2 vent-free gas log set of no more than 40,000 Btu/hr whose minimum firebox size fits this firebox (see the log set's manual); sold separately
Optional – Liners:
Optional – Accessories:
Optional – Extended hood (needed when the facing material is more than 1" thick, such as stone or brick):
Optional – Louvers (louvered models only):
Optional – Door set (needs the VBY32TBL door frame with barrier):
-
Door Set, Black, Mission Arch (VBR32TMBL)
-
Door Set, Hammered Pewter, Mission Arch (VBR32TMHP)
-
Door Set, Black, Arch (VBR32TCBL)
-
Door Set, Hammered Pewter, Arch (VBR32TCHP)
-
Door Frame, Black, Arch (VBY32TBL)
Optional – Outer frame, for louvered models:
Specifications
| Model numbers |
VFP32FB0F, VFP32FB0L |
| Type |
Universal vent-free firebox (ANSI Z21.91 ventless fireplace enclosure) |
| Log set |
Required, sold separately: a listed ANSI Z21.11.2 vent-free gas log set of no more than 40,000 Btu/hr whose minimum firebox size fits this firebox (check the log set's manual) |
| Framing (rough opening) |
35 3/8" W x 38 7/8" H x 20 9/16" D |
| Firebox dimensions |
34.9" W x 38.2" H x 20.6" D (without standoffs and nailing flanges) |
| Firebox opening |
31" x 27.4" (W x H) |
| Front |
Flush (model ending F) or louvered (model ending L) |
| Liner |
Optional |
| Hood |
Black hood included |
| Gas connection |
3/8" line for the log set, either side |
| Blower and light |
Optional (FBB5 blower, LK3 lighting kit) |
| Manufactured (mobile) home |
May be installed in an aftermarket, permanently located manufactured home (USA only) or mobile home where local codes allow |
| Style |
Traditional |
Installation Requirements
-
Log set: install only a listed ANSI Z21.11.2 vent-free gas log set of no more than 40,000 Btu/hr that fits this firebox, and follow the log set's own instructions, including its room-size and bedroom/bathroom rules, as well as this manual.
-
Clearances: the side and back flanges are zero clearance to combustibles; keep at least 6" from the inside of the firebox to a perpendicular combustible side wall.
-
Top and framing: combustible finishing materials need 3/4" clearance to the top of the unit (two shoulder bolts on the unit keep this gap); frame with 2 x 4 lumber or heavier. Install the non-combustible board supplied with the firebox before adding paint, tile or stone above it.
-
Ceiling: at least 84" from the bottom of the firebox to the ceiling.
-
Front: leave at least 36" clear in front of the firebox. The supplied hood (or an optional hood) must be installed before use.
-
Mantel: a combustible mantel must meet the mantel chart in the installation manual.
-
Floor: on carpet, tile or any combustible floor other than wood, set the firebox on a metal or wood panel the full width and depth of the unit. Hearth extensions are recommended but not required.
-
Gas: the firebox takes a 3/8" gas line for the log set, through access holes on either side; propane installs need an external regulator limiting supply pressure to 14" w.c. In Massachusetts a flexible connector may not exceed 3 ft, the installation must be made by a licensed plumber or gas fitter, and unvented heaters are not allowed in bedrooms or bathrooms.
-
Power: only needed for the optional blower or light: the junction box on the lower right must be pre-wired when the firebox is installed, grounded per code, controlled by a wall switch or the SCV1 speed control.
-
Installation: must be installed by a qualified installer per the installation manual and local codes.
Make It Yours: Liners, Doors and Light
The liner sets the backdrop for the logs: aged brick, banded brick, traditional brick or stacked limestone.
Arch and mission arch door sets come in black or hammered pewter and mount on the door frame with barrier (VBY32TBL). Louvered models take arch or mission louvers and a steel outer frame in black or hammered pewter, with a hammered pewter bottom trim kit, to finish the face. The LK3 lighting kit, run from a switch or rheostat, lights the firebox, and the EK1 ember kit adds glow to the bed.
Bring the Breckenridge Premium 32" Home with Dreamwood Living
The Premium 32" suits a wall where you want a taller vent-free log fire without running a chimney or vent pipe.
Reach out to our team and we will help you match a vent-free log set to the firebox and pick the liner, front and lighting.
FAQs
Which Breckenridge is right for me?
The Premium 32" is 20.6" deep with a 31" x 27.4" opening, in flush or louvered models. The Breckenridge comes in three trims, all built for a listed vent-free log set up to 40,000 Btu/hr. Deluxe (32", 36" and 42") is the shallowest, 16 1/2" deep for the 32" and 19" for the 36" and 42", in flush or louvered models, some with a refractory liner included. Premium (32", 36" and 42") is 20.6" deep with a taller 27.4" opening, flush or louvered. Select (32", 36" and 42") is flush only and 23 3/16" deep, with a 31 5/8" tall opening. There are also Premium 36" see-through and peninsula models, which come with a banded brick liner.
What do I need to order with it?
A listed ANSI Z21.11.2 vent-free gas log set of no more than 40,000 Btu/hr whose minimum firebox size fits this firebox; check the log set's manual. Liners, doors, louvers, the blower and the lighting kit are optional. If the facing is more than 1" thick, such as stone or brick, add the extended hood (VB4H32BL).
Does it need a chimney or vent?
No. It is a vent-free firebox, so there is no chimney or vent pipe. It takes a 3/8" gas line for the log set, and power is only needed for the optional blower or lighting kit. The log set's own manual sets the rules for the room it goes in, and some areas limit vent-free appliances; our direct vent vs. vent-free guide covers where vent-free isn't allowed.
How big is the framing?
35 3/8" wide, 38 7/8" high and 20 9/16" deep.
Documents & Downloads
Warranty
Empire limited warranty for Breckenridge vent-free fireboxes, from the warranty section of the installation manual:
- Combustion chamber and heat exchanger: limited lifetime parts, with 5 years of limited labor
- All other components, except remote controls, thermostats, accessories and replacement parts: 5 years parts and labor
- Remote controls, thermostats, accessories and parts: 1 year parts
The vent-free log set installed in the firebox has its own warranty. The firebox warranty applies to the original purchaser. Full terms, including what is not covered, are in the warranty section of the installation manual.