The Empire Innsbrook Large is a direct-vent gas fireplace insert that turns an existing wood-burning fireplace into a gas log fire, up to 28,500 Btu/hr on natural gas or 27,500 on propane, venting up the chimney through two 3" flexible liners. It comes with a ceramic fiber log set and a factory-installed blower.

Model numbers DVC28IN31N and DVC28IN31P are millivolt, with a standing pilot that needs no house power; DVC28IN71N and DVC28IN71P are intermittent pilot, with battery backup. N is natural gas and P is propane. A surround is required, and the insert is approved for bedrooms in the US and Canada.

Video

Play video: Empire Innsbrook Large direct-vent gas fireplace insert video

The Innsbrook Large: A Direct Vent Gas Insert for Your Wood-Burning Fireplace

The insert is 34 3/16" wide at the front (21 3/4" at the rear), 23 1/2" high and 16 5/8" deep. It fits a listed wood-burning masonry or factory-built fireplace with an opening of at least 23 1/2" high, 34 1/4" wide at the front, 22" at the rear and 16 5/8" deep, and a flue at least 8" in diameter.

The two liners, one for intake and one for exhaust, run up the existing chimney 10 ft to 35 ft to a vertical termination cap. The original non-combustible hearth stays, at least 16" deep in front, and the blower plugs into a 120V outlet in the old firebox or on the hearth.

See every model in our gas fireplace inserts collection, or browse all direct vent gas inserts.

Deciding between a new fireplace and an insert? Our guide to fireplace vs. fireplace insert explains the difference. Weighing vent-free against direct vent? Our guide to direct vent vs. vent-free gas fireplaces covers the pros, the cons and where vent-free isn't allowed. Choosing between millivolt and intermittent pilot? Our guide to millivolt vs. electronic ignition gas fireplaces explains the difference.

Features

  • Heat: up to 28,500 Btu/hr on natural gas or 27,500 on propane.
  • Log set and blower included: a ceramic fiber log set with glowing embers, and a factory-installed blower with variable speed control.
  • Direct vent: two 3" flexible liners up the existing chimney, 10 ft to 35 ft, vertical termination only.
  • Approved for bedrooms: in the US and Canada.
  • Millivolt or intermittent pilot: millivolt models (31) run without house power and intermittent pilot models (71) have battery backup; both come with an on/off switch.
  • Surround required: cast iron with its adaptor kit, steel in black or bronze, or a custom 3-sided or 4-sided surround.
  • Decorative fronts: Lancaster, Horizon and Transom fronts and doors fit the steel surrounds.
  • Optional liners: traditional aged brick, washed brick, black porcelain or banded brick.

Package Contents

  • Innsbrook Large direct-vent gas fireplace insert
  • Ceramic fiber log set and glowing embers
  • Factory-installed blower
  • Barrier screen
  • On/off switch
  • Four AA backup batteries (intermittent pilot models)

A surround is required and vent pipe is ordered separately (see below).

What to Order With It

The insert ships with its log set, glowing embers, barrier screen, blower and on/off switch; intermittent pilot models also include four AA batteries for backup. Vent pipe is ordered separately.

Required – Surround (choose one; the cast iron surround needs the SAK adaptor kit and does not take a decorative front or bottom cover):

Optional – Bottom cover (when a steel surround does not reach the floor):

Optional – Shroud (used with a surround to cover a larger fireplace opening):

Optional – Decorative fronts and doors (need a steel surround):

Optional – Liners:

Optional – Remotes and wall controls:

Optional – Variable flame remote kit (intermittent pilot models only):

Optional – Conversion kits:

Specifications

Model numbers DVC28IN31N, DVC28IN31P, DVC28IN71N, DVC28IN71P
Insert dimensions 34 3/16" W (front) x 23 1/2" H x 16 5/8" D; rear width 21 3/4" (depth behind the surround)
Surround size 28 1/4" H; 40" W with 3" sides or 46" W with 6" sides
Barrier screen opening 31 15/16" x 20 1/2" (W x H)
Fuel Natural gas (N) or propane (P); a certified conversion kit is available
Type Direct-vent fireplace insert
Input, maximum 28,500 Btu/hr natural gas; 27,500 Btu/hr propane
Input, minimum 18,500 Btu/hr natural gas; 21,000 Btu/hr propane
Venting Two 3" flexible aluminum or stainless liners (intake and exhaust), vertical termination only, 10 to 35 ft
Control Millivolt standing pilot (models with 31) or intermittent pilot with battery backup (models with 71); on/off switch included
Blower Factory-installed, with automatic fan switch and variable speed control
Logs Ceramic fiber log set included
Gas connection 1/2" NPT flex line with shutoff valve, right side
Listing ANSI Z21.88/CSA 2.33
Bedroom May be installed in a bedroom or bed-sitting room (USA and Canada)
High altitude Above 2,000 ft in the US the input may need to be reduced with a smaller orifice; see the manual
Manufactured (mobile) home May be installed into a listed wood-burning fireplace in an aftermarket, permanently located manufactured home (USA only) or mobile home where state or local codes allow
Style Traditional

Installation Requirements

  • Fireplace: installs in a listed wood-burning masonry or factory-built fireplace with a minimum opening of 23 1/2" H x 34 1/4" front width x 22" rear width x 16 5/8" deep, and a flue at least 8" in diameter. The damper may need to be removed. A factory-built fireplace that has been modified for the insert cannot go back to burning wood.
  • Hearth: the original non-combustible hearth must stay, extending the width of the fireplace and at least 16" in front; wood flooring, vinyl or carpet may not be directly in front of the insert.
  • Clearances: at least 8" from the edge of the barrier screen frame to a perpendicular combustible side wall; 1/4" to combustible material under the insert. Nothing combustible may go behind the surround or the insert.
  • Mantel and trim: a combustible mantel or trim must meet the mantel and trim chart in the installation manual.
  • Venting: two 3" flexible aluminum or stainless liners (intake and exhaust) run up the existing chimney to a vertical termination cap, from 10 ft up to 35 ft. Horizontal termination is not allowed, and the cap must sit in open air, not under a cap shared with other flues.
  • Power: a 120V cord for the blower is included; plug it into an outlet in the old firebox or on the hearth, with GFCI protection where codes require.
  • Installation: must be installed by a qualified installer per the installation manual and local codes. In Massachusetts the installation must be done by a licensed plumber or gas fitter.

Make It Yours: Surround, Front and Liner

The steel surrounds come in black or bronze with 3" sides and a 6" top, 6" sides and a 6" top, or 6" sides and a 9" top (28 1/4" high, 40" wide with 3" sides or 46" with 6" sides), and a matching bottom cover fills the gap when the surround stops short of the floor. The black cast iron surround (SC356BL) needs the SAK28 adaptor kit and does not take a decorative front or bottom cover, and custom 3-sided and 4-sided surrounds are available. The SH1BL shroud, 48" x 35 3/4" with a bottom panel, covers a larger fireplace opening.

With a steel surround, add the Lancaster front in black or bronze, the Horizon front or the Transom doors. Inside, choose a traditional aged brick, washed brick, black porcelain or banded brick liner. Controls run from an on/off remote (FRBC) or wall switch (FWS1) to a thermostat remote (FRBTC2), a programmable touchscreen remote (FRBTPS) and wall thermostats (the TMV reed switch or the TRW wireless). On intermittent pilot models, the variable flame remote kit (RVKN or RVKP) adds a stepper motor and thermostat remote for flame adjustment.

Bring the Innsbrook Large Home with Dreamwood Living

The Innsbrook Large suits a living room, family room or bedroom with a wood-burning fireplace you would rather run on gas.

Reach out to our team and we will help you measure the fireplace and pick the surround, front and liner.

FAQs

Which Innsbrook is right for me?

The Innsbrook Large (DVC28IN) is the 28,500 Btu/hr direct-vent model. Every Innsbrook is a traditional gas insert with a log fire for an existing wood-burning fireplace, and every one needs a surround. The direct-vent Innsbrook Small, Medium and Large (DVC20IN, DVC26IN and DVC28IN) vent up the chimney through two 3" flexible liners, come with a ceramic fiber log set and a blower, run up to 20,500, 26,000 or 28,500 Btu/hr and are approved for bedrooms. The vent-free Innsbrook inserts need no chimney or vent and can also be built into a framed wall: the VFPC20 (20,000 Btu/hr) comes with its log set, brick liner and blower, and the VBPC28 (28,000 Btu/hr) comes with its blower and takes a log set and liner ordered separately.

Will it fit my fireplace?

It needs a listed wood-burning masonry or factory-built fireplace with an opening of at least 23 1/2" high, 34 1/4" wide at the front, 22" at the rear and 16 5/8" deep, and a flue at least 8" in diameter. The damper may need to be removed, and a factory-built fireplace modified for the insert cannot go back to burning wood.

What venting does it need?

Two 3" flexible aluminum or stainless liners, one for intake and one for exhaust, run up the existing chimney to a vertical termination cap, from 10 ft to 35 ft. Horizontal termination is not allowed, and vent pipe is ordered separately.

Can it go in a bedroom?

Yes. It may be installed in a bedroom or bed-sitting room in the US and Canada.

Can I switch it between natural gas and propane?

Yes, with the conversion kit for its control: 36400 (natural gas to propane, millivolt), 36399 (propane to natural gas, millivolt), 36727 (natural gas to propane, intermittent pilot) and 36726 (propane to natural gas, intermittent pilot).

Documents & Downloads

Warranty

Empire limited parts warranty, from the warranty section of the installation manual:

  • Combustion chamber, heat exchanger and factory-installed glass: limited lifetime
  • All other components, except remote controls, thermostats, accessories and replacement parts: 3 years
  • Remote controls, thermostats, accessories and parts: 1 year

The warranty covers parts for the original purchaser. Full terms, including what is not covered, are in the warranty section of the installation manual.