Empire Rushmore 40" Clean-Face Direct Vent Gas Fireplace

SKU DVCT40CBP95N
Original price $6,555.00 - Original price $6,555.00
Original price
$6,555.00
$6,555.00 - $6,555.00
Current price $6,555.00

Free Shipping over $299


Please contact us directly to request quote for Empire products. 

  • FREE SHIPPING : All Over United States over $299

  • SPEAK TO AN EXPERT : Call 888-486-2909 or email at cs@dreamwoodliving.com

Empire Rushmore 40" Clean-Face Direct Vent Gas Fireplace

The Empire Rushmore 40" (model numbers DVCT40CBP95N for natural gas and DVCT40CBP95P for propane) is a clean-face, zero-clearance direct-vent gas fireplace with a TruFlame dual burner behind a ceramic glass front. It frames into a 49 1/2" wide opening.

It runs from a multi-function remote that sets the flame height of each burner, turns the rear burner off, dims the accent light and runs the optional blower, with battery backup for power outages. A log set and a liner are required and ordered separately; fronts, frames, a blower and heat management kits can be added.

Key Features

  • Up to 47,500 Btu/hr input on natural gas and 45,000 Btu/hr on propane
  • Ceramic glass, 36" x 30 3/8" (W x H)
  • TruFlame dual burner; the rear burner turns off from the remote
  • Multi-function remote with thermostat, flame height, accent light dimming and blower speed
  • Battery backup for power outages
  • Log set and liner required, ordered separately
  • Optional twin blower, forged iron fronts and beveled frames

What to Order With It

The fireplace ships with its barrier screen, remote and non-combustible board. It needs a log set and a liner before it can run.

Required – Log set (choose one):

Required – Liner (choose one):

Optional – Forged iron fronts (an inset needs the matching forged iron frame):

Optional – Beveled frames:

Optional – Blower (easier to fit before the fireplace is framed in):

Optional – Heat management:

Optional – Vent kits:

Optional – Conversion kits:

Specifications

Model numbers DVCT40CBP95N, DVCT40CBP95P
Framing (rough opening) 49 1/2" W x 55 1/2" H x 24" D
Appliance dimensions 49" W x 42 3/4" H x 24" D
Fireplace opening 40 7/8" x 36 1/2" (W x H)
Glass Ceramic glass, 36" x 30 3/8" (W x H)
Fuel Natural gas (N) or propane (P); field conversion with a certified kit
Input, maximum 47,500 Btu/hr natural gas; 45,000 Btu/hr propane
Input, minimum 30,000 Btu/hr natural gas, 35,000 Btu/hr propane with both burners on; 15,000 / 16,500 Btu/hr with the front burner only
Venting Direct vent, 5" x 8", top only
Control Intermittent pilot with multi-function thermostat remote (front and rear burner flame height, rear burner on/off, accent light dimming, blower speed) and battery backup
Burner TruFlame dual burner (front and rear) with ceramic catalyst
Accent light Built in, dimmable from the remote
Blower Optional (FBB21)
Log set and liner Required, ordered separately
Barrier screen Included
Gas connection 1/2" NPT, entering on the fireplace's right side
Installation type Zero clearance
Listing ANSI Z21.88/CSA 2.33
Bedroom May be installed in a bedroom or bed-sitting room (USA and Canada)
High altitude Above 2,000 ft in the US the input may need to be reduced with a smaller orifice; see the manual
Manufactured (mobile) home May be installed in an aftermarket, permanently located manufactured home (USA only) or mobile home where local codes allow
Style Traditional, clean-face

Installation Requirements

  • Clearances to combustibles: back 0", sides 2", floor 0", top framing edge 0". Keep at least 6" from the fireplace opening to a perpendicular side wall.
  • Ceiling: at least 35" from the top of the fireplace opening to the ceiling.
  • Mantel: a combustible mantel can project 2" at 12" above the fireplace opening, up to 12" at 22"; follow the mantel chart in the installation manual.
  • Facing: only non-combustible material may finish the face of the fireplace; the non-combustible board goes over the appliance as the manual shows.
  • Framing: use 2 x 4 lumber or heavier.
  • Venting: 5" x 8" direct vent from the top only (rear venting is not allowed), with at least 12" of vertical pipe before any horizontal run. Horizontal runs follow the vent graph in the manual, up to 18 ft, less 18" for each 45° elbow and 36" for each 90° elbow in the horizontal run; no more than three 90° and two 45° elbows. Island and room-divider installs need at least 8 ft of vertical rise for an 18 ft horizontal run.
  • Power: a 120V, 60Hz, 1 A supply, entering on the right side. A battery backup pack lets the fireplace run in a power outage; the accent light and blower will not run without power.
  • Installation: must be installed by a qualified installer per the installation manual and local codes. In Massachusetts the installation must be done by a licensed plumber or gas fitter.

Video

Downloads

Warranty

Empire limited parts warranty, from the warranty section of the installation manual:

  • Combustion chamber, heat exchanger and factory-installed glass: limited lifetime
  • All other components, except remote controls, thermostats, accessories and replacement parts: 3 years
  • Remote controls, thermostats, lighting system, accessories and parts: 1 year

The warranty covers parts for the original purchaser. Full terms, including what is not covered, are in the warranty section of the installation manual.