Empire 5" x 8" Direct Vent Horizontal Thru-the-Wall Flex Vent Kit

The Empire DVVK5F is the horizontal thru-the-wall flex vent kit for Empire direct-vent fireplaces with 5" x 8" venting. It takes the vent out through the wall with 48" of flex pipe, a wall thimble and a termination cap.

Fits

Empire fireplaces on our site whose pages offer the DVVK5F. The kit is for direct vent fireplaces listed for use with it, so check the venting section of your fireplace manual.

  • Empire Tahoe Clean Face Peninsula: 36"
  • Empire Tahoe Clean Face See-Through: 36"

Package Contents

  • Termination cap and deflector shield
  • Wall firestop/thimble assembly
  • 5" x 48" two-ply aluminum flex with starter collar
  • 8" x 48" two-ply aluminum flex
  • Two 5" clamps, two 8" clamps and three spacer springs
  • Screws

Related Parts

Specifications

Model numbers DVVK5F
Venting 5" x 8" direct vent
Flex length 48" (5" inner flue and 8" outer air pipe)
Termination Horizontal, through the wall

Installation Notes

  • Connection: the 8" flex attaches to the 8" vent adapter collar on the fireplace. Stretch the flex to 48", then trim the extra, leaving enough to connect to the cap.
  • Rise: the vent must rise toward the cap and never run level or slope down. The Tahoe Clean Face Peninsula and See-Through manual calls for at least 1/2" of rise per foot.
  • Clearances: keep 3" above and 1" at the sides and bottom of the horizontal pipe until it passes through the wall, and 1" all around at the wall firestop.
  • Flex rules: do not mix the flex with rigid pipe or join two flex sections without approved connectors. Support horizontal runs every 3 ft.
  • Cap: do not recess the cap into the wall or siding, and mount it with the drain holes at the bottom. Cap placement and outside clearances come from the fireplace manual.
  • Installation: must be installed by a qualified installer following the fireplace manual and local codes. In Massachusetts, gas work must be done by a licensed plumber or gas fitter.