Empire 18" Flint Hill Ceramic Fiber Gas Log Set with Vent-Free Contour Burner

SKU VFDM18LBN
Empire authorized dealer
Original price $649.00 - Original price $835.00
Original price
$649.00
$649.00 - $835.00
Current price $649.00

Free Shipping over $299


Please contact us directly to request quote for Empire products. 

Not sure which options you need? Call 888-486-2909Chat with us

Empire 18" Flint Hill Ceramic Fiber Gas Log Set with Vent-Free Contour Burner

The Empire 18" Flint Hill set (model numbers VFDR18LB10N, VFDR18LB10P, VFDR18LBN, VFDR18LBP, VFDT18LBN, VFDT18LBP, VFDM18LBN and VFDM18LBP; N for natural gas, P for propane) puts a 5-piece ceramic fiber log set on Empire's vent-free contour burner, with glowing embers included. It needs as little as 12" of firebox depth, so it fits most existing wood-burning fireplaces and listed vent-free fireboxes.

Choose a millivolt burner with an on/off switch (VFDR), a standing-pilot thermostat burner with high/low knob (VFDT) or a manual burner with high/medium/low knob (VFDM). The 10,000 Btu VFDR18LB10 is the size for bedrooms where local codes allow. The VFDR and VFDM models can also be installed as vented decorative appliances with the damper clamped open.

Key Features

  • 5-piece ceramic fiber logs on a vent-free contour burner, embers included
  • Up to 28,000 Btu/hr (10,000 Btu bedroom model too)
  • Millivolt (VFDR), thermostat (VFDT) or manual (VFDM) control
  • Needs as little as 12" of firebox depth
  • Oxygen depletion sensor shuts it off if fresh air runs low
  • Vent-free, or vented (VFDR and VFDM) with the damper clamped open

What to Order With It

The set ships with the burner and grate, the 5-piece ceramic fiber logs, a bag of glowing embers and anchor screws.

Optional – Embers and hood:

Optional – Remote, wall switch and thermostats (millivolt VFDR models only):

Fireboxes it fits (optional; any approved fireplace or firebox that meets the minimum size works):

Specifications

Model numbers VFDR18LB10N, VFDR18LB10P, VFDR18LBN, VFDR18LBP, VFDT18LBN, VFDT18LBP, VFDM18LBN, VFDM18LBP
Size 18" log set
Logs 5-piece ceramic fiber; glowing embers (rock wool) included
Type Unvented (vent-free) gas log heater; VFDR and VFDM models also certified as vented decorative appliances (ANSI Z21.60)
Input, maximum 28,000 Btu/hr, natural gas and propane; 10,000 Btu/hr on the VFDR18LB10 bedroom models
Input, minimum 19,000 natural gas / 22,000 propane (Btu/hr); the 10,000 Btu models are single rate
Input, medium (VFDM) 23,000 natural gas / 25,000 propane (Btu/hr)
Control, VFDR Millivolt standing pilot with on/off switch; no house power needed; optional remote, wall switch or thermostat
Control, VFDT Standing pilot with thermostat and high/low knob (vent-free use only)
Control, VFDM Standing pilot with manual high/medium/low knob
Safety Oxygen depletion sensor (pilot safety system) shuts the burner off if fresh air runs low
Fuel Natural gas (N) or propane (P); field conversion not permitted
Minimum firebox 28" front width, 17" rear width, 12" deep, 17" high (from the installation manual)
Style Traditional
Manufactured homes May be installed in an aftermarket manufactured (mobile) home where local codes allow
High altitude Above 2,000 ft the input may need to be reduced 4% per 1,000 ft; check with the gas utility

Installation Requirements

  • Where it can go: in a solid-fuel-burning masonry or UL 127 factory-built fireplace, or a listed vent-free firebox; not in a factory-built fireplace whose instructions say it should not be used with unvented gas logs. Have the chimney and firebox cleaned first, and seal any fresh-air vents or ash doors in the firebox.
  • Firebox size: the fireplace or firebox opening must be at least 28" front width, 17" rear width, 12" deep, 17" high. With glass doors, use the door frame opening as the front width; the doors must be fully open whenever the logs burn.
  • Room size: the room must be an unconfined space of at least 50 cubic feet per 1,000 Btu/hr of input of all gas appliances drawing air from it, or extra combustion and ventilation air must be provided as the National Fuel Gas Code describes. Vent-free heaters are for supplemental heat, not as a primary heat source.
  • Bedrooms and bathrooms: an unvented heater over 10,000 Btu/hr may not go in a bedroom or bathroom, and one over 6,000 Btu/hr may not go in a bathroom. Only the 10,000 Btu/hr VFDR18LB10 models can go in a bedroom, where local codes allow; no model can go in a bathroom. Massachusetts prohibits unvented gas heaters in bedrooms and bathrooms.
  • Clearances: the sides of the fireplace opening at least 6" from any combustible wall; a ceiling at least 41" above the opening.
  • Mantel: non-combustible material must extend at least 12" above the opening, or 8" with the optional ELH1 hood. A combustible mantel must meet the mantel chart in the installation manual; otherwise run a VFDR or VFDM set as a vented appliance with the damper open.
  • Vented use: VFDR and VFDM models can be installed as vented decorative appliances with the damper clamped open; thermostats may not be used in a vented installation, and VFDT models are vent-free only.
  • Log placement: each log goes in the position shown in the manual; spread the embers in a single thin layer and keep them off the large burner ports.
  • Installation: must be installed by a qualified installer per the installation manual and local codes, with the grate anchored to the firebox floor. In Massachusetts the installation must be done by a licensed plumber or gas fitter.

Videos

Play video: Empire 18 inch Flint Hill contour log set page: Empire 18 inch Flint Hill log set with contour burner

Downloads

Warranty

Empire limited warranty, from the warranty section of the installation manual:

  • All other components, except remote controls, thermostats, accessories and replacement parts: 5 years parts and labor
  • Remote controls, thermostats, accessories and parts: 1 year parts

The warranty applies to the original purchaser. Full terms, including what is not covered, are in the warranty section of the installation manual.