Performance
| Maximum heat output (dry cordwood) | 45,000 BTU/h (13.2 kW) |
| Overall heat output range | 12,124 – 26,700 BTU/h (3.55 – 7.83 kW) |
| Recommended heating area | 250 – 1,200 sq ft (23 – 111 m²) |
| Average overall efficiency (HHV) | 74% |
| Average overall efficiency (LHV) | 79% |
| Optimum overall efficiency | 79% |
| Average particulate emissions | 1.8 g/h (EPA / CSA B415.1-10) |
| Maximum burn time | 5 hours |
| Overall firebox volume | 1.8 cu ft (0.051 m³) |
| EPA loading volume | 1.55 cu ft (0.044 m³) |
| Recommended log length | 16" (406 mm), loaded north-south |
| Blower | Optional, up to 100 CFM |
Specifications
| Combustion technology | Non-catalytic |
| High-efficiency certified appliance | Yes, EPA 2020 approved |
| Fuel type | Dry cordwood |
| Maximum log length | 17" |
| Log positioning | Loading over depth |
| Chimney diameter | 6" |
| Flue outlet diameter | 6" |
| Type of chimney | UL 103 HT (2100 °F) |
| Minimum chimney height | 12' |
| Baffle type | C-Cast or equivalent |
| Approved for an alcove installation | Yes |
| Approved for a mobile home installation | Yes, with fresh air intake |
| Shipping Weight | 317 lb (144 kg) |
| Door type | Single, glass with cast iron frame |
| Glass type | Ceramic glass |
| Glass surface – dimensions (Width X Height) | 10 1/4" x 8 7/8" |
| Glass air-wash system | Yes |
| Overall dimension (Height) | 28 7/8'' |
| Overall dimension (Width) | 20 1/4'' |
| Overall dimension (Depth) | 27 7/8'' |
| Door opening – dimension (Height) | 7 5/8" |
| Door opening - dimension (Width) | 12" |
| Firebox – dimension (Height) | 11 3/4" |
| Firebox – dimension (Width) | 14 1/4" |
| Firebox – dimension (Depth) | 19 1/8" |
| Firebox lined with refractory bricks for better heat distribution | Yes |
| Stainless-steel secondary-air system improving gas combustion | Yes |
| Steel thickness – body | 3/16" |
| Steel thickness – top | 5/16" |
| USA standard (emissions) | EPA |
| USA standard (safety) | UL 1482, UL 737 |
| Tested and listed as per applicable standards | By an accredited laboratory |
| Warranty | Limited lifetime |
Clearances to Combustibles
Osburn publishes these as lettered dimensions A to F that are defined on the clearance drawings in the installation manual, not in words — so read this table with the manual open rather than assuming which letter is which wall. The number that decides whether the stove fits your room is the smallest one: 11" with a single-wall connector pipe, 6" with a double-wall connector pipe (USA). Upgrading the pipe is almost always cheaper than moving a wall.
| Dimension | Single wall (USA) | Double wall (USA) |
| A | 12" (305 mm) | 6" (152 mm) |
| B | 12" (305 mm) | 12" (305 mm) |
| C | 11" (279 mm) | 6" (152 mm) |
| D | 16" (406 mm) | 9 1/4" (235 mm) |
| E | 18" (457 mm) | 18" (457 mm) |
| F | 18" (457 mm) | 12 7/8" (327 mm) |
The manual states it plainly: no part of the stove or flue pipe may be located closer to combustibles than these figures.
Floor Protection
A non-combustible floor pad is required on a combustible floor. It must extend:
| Direction | USA |
| In front of the door opening | 16" (406 mm) |
| To the sides and rear | 8" (203 mm) |
Alcove and mobile-home installations are both approved for this stove and each has its own reduced clearance set. See the installation guide below for those configurations, for the full floor-pad dimensions, and for the heat-shield options that reduce clearances further.